Close Panel

HRP serie
Compacte electromagnetische doseerpompen



DC power voltage / vertically- or horizontally- oriented pump head

The HRP series is powered by 12VDC or 24VDC and offers an ideal fit for built-in applications. Select vertically- or horizontally-oriented pump head to get optimum mounting position in various host machines.

High resolution

Digitally-controlled spm range is 0-720spm. The minimum flow of 0.055ml per shot offers a constant imperceptible injection.

Waterproof and dustproof structure

The sealed drive unit and control unit are enclosed to a water/dust-proof rating of IP65. • This pump is not completely water resistant. Protect the pump with a cover when installing it out of doors. Operational function HRP pumps are controlled by an external signal and are available in the following types.

Pulse control type

A pulse signal input controls pump operation (stroke rate). The pump makes one shot per pulse synchronously. • An input signal is required to enable operation in addition to power activation for this type. • The pump can not exceed a maximum of 720spm, even if the external signal input instructs the pump to run beyond that speed.

4-20mA control type

The input of 4-20mA proportionally controls the pump operation (stroke rate). • An input signal is required to enable operation in addition to power activation for this type.

1-5V control type

The input of 1-5V proportionally controls the pump operation (stroke rate). • An input signal is required to enable operation in addition to power activation for this type.

Stop control type

The input of the stop signal suspends the pump operation. • The type of pump starts to run at 720spm upon power activation.

Specificaties
gewicht 0.5kg
Power voltageDC12V
Power consumption 5.6V
Tube connection bore 3 X 6, 4 X 6, 1/8 X 1/4
Stroke rate0 to 720 spm
Max. discharge pressure 0.2 MPa
Flow rate 38 mL/min
Current value 1.5A